施工圍擋安裝和設(shè)置規(guī)范是什么?
來(lái)源:http://www.sytyhy.net/ 發(fā)布時(shí)間:2023-11-13
施工圍擋在城市的建設(shè)中發(fā)揮著美麗、清潔和統(tǒng)一的作用,是現(xiàn)在城市建設(shè)中不可缺少的施工設(shè)備,施工圍欄的高度通常在2米以上,常見(jiàn)的有2米、4米、6米和8米,或更高的12米等。
Construction fences play a beautiful, clean, and unified role in urban construction, and are now indispensable construction equipment in urban construction. The height of construction fences is usually over 2 meters, commonly 2 meters, 4 meters, 6 meters, and 8 meters, or 12 meters higher.
施工圍欄高度在4米以下的,一般采用單柱式,在地下深處挖1米左右的基礎(chǔ),專欄采用直徑為140mm和189mm等,施工圍欄高度在4米以上的一般采用二柱式,地下深挖的基礎(chǔ)通過(guò)調(diào)整高度來(lái)調(diào)整,兩根柱子采用直徑114mm-219mm的柱子,施工圍擋表面鍍鋅,一般采用0.5mm的厚度。
For construction fences with a height of less than 4 meters, a single column type is generally used. A foundation of about 1 meter is excavated deep underground, and columns with diameters of 140mm and 189mm are used. For construction fences with a height of more than 4 meters, a two column type is generally used. The foundation of deep underground excavation is adjusted by adjusting the height. The two columns are columns with a diameter of 114mm-219mm, and the surface of the construction fence is galvanized with a thickness of 0.5mm.
施工圍擋的安裝設(shè)置規(guī)范:
Installation and setting specifications for construction fences:
1、工程施工作業(yè)應(yīng)在施工現(xiàn)場(chǎng)周圍設(shè)置施工圍擋進(jìn)行防護(hù),施工圍擋設(shè)置應(yīng)堅(jiān)固、穩(wěn)定、美觀,禁止在施工圍擋上進(jìn)行涂鴉,施工圍擋腳下應(yīng)控制垃圾, 施工圍擋的清潔。
1. Engineering construction operations should be protected by setting up construction fences around the construction site. The construction fences should be sturdy, stable, and aesthetically pleasing. Graffiti is prohibited on the construction fence. Garbage should be controlled at the foot of the construction fence, and the construction fence should be clean.
2、市政道路工程、管線、給排水工程圍材選用藍(lán)色夾層鋼板(厚50mm)或PVC材料(厚20mm),圍柱為角鋼,上下有側(cè)邊,顏色為白色。施工圍擋總高2.2m,柱距3m,施工圍擋下腳須設(shè)置基座,基座做成四塊混凝土砌塊,具體規(guī)格參照施工圍擋設(shè)計(jì)圖紙,施工圍擋下腳須用油漆涂成黃色與黑色相間的交通提醒標(biāo)志,園林綠化工程、應(yīng)急搶修工程的施工圍擋材料、規(guī)格應(yīng)按照施工相關(guān)圖紙制作,而且不得在上面涂鴉。
2. The enclosure materials for municipal road engineering, pipelines, and water supply and drainage engineering shall be blue laminated steel plate (50mm thick) or PVC material (20mm thick). The enclosure columns shall be angle steel with side edges at the top and bottom, and the color shall be white. The total height of the construction fence is 2.2m, with a column spacing of 3m. A base must be set up at the bottom of the fence, and the base should be made of four concrete blocks. The specific specifications should refer to the construction fence design drawings. The bottom of the fence must be painted with yellow and black traffic safety warning signs. The construction fence materials and specifications for garden green chemical engineering and emergency repair engineering should be made according to the relevant construction drawings, and graffiti is not allowed on it.
3、施工圍擋應(yīng)包圍兩側(cè)支撐臺(tái)底部,將膨脹螺栓固定成一列,三根間隔一致。
3. The construction fence should surround the bottom of the support platforms on both sides, and fix the expansion bolts in a row with consistent spacing between the three.
4、距交通口20m以內(nèi)設(shè)置施工圍擋時(shí),施工圍擋上部0.8m以上的部分應(yīng)采用透明施工圍擋,不得影響交通口的交通質(zhì)量。
4. When a construction fence is set up within 20 meters from the traffic exit, transparent construction fences should be used for the part above 0.8 meters of the construction fence, which should not affect the traffic quality of the traffic exit.
5、禁止用容易生銹、破裂、破損的材料建造施工圍擋。
5. It is prohibited to use materials that are prone to rusting, cracking, or damage to construct construction fences.
6、在施工圍擋入口端和交叉口的柱子上每隔6米安裝一盞警告燈,在施工圍擋兩端的端部設(shè)置防撞桶。
6. Install a warning light every 6 meters on the columns at the entrance and intersection of the construction fence, and set up anti-collision buckets at the ends of the construction fence.